S6062-18/30A (D) Series Electric Actuator

Certification: ISO, CE
Power Supply: AC DC24V AC230V
Power Source: Electric Power
Temperature: Ordinary Temperature
Transport Package: Cartons
Trademark: SOLOON
Samples:
US$ 60/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Beijing, China
to see all verified strength labels (30)

Basic Info.

Origin
China
Production Capacity
1000per Month

Product Description

S6062-18/30A (D) Series Electric Actuator

Features of S6062-18/30A (D) Series Electric Actuator

 

  • Closing force S6062-18A/D is 1800N; Closing force S6062-30A/D is 3000N;

  • The action is transmitted by gears, and the center gear is a roller that rotates around the central axis;

  • Straight stroke indicator;

  • When the drive reaches the limit position, a delay will occur for a period of time to ensure that the valve is opened or closed.

 

Note of S6062-18/30A (D) Series Electric Actuator

 

  • When adjusting the medium temperature medium, the grease on the drive needs to be replaced every three months (for example water).

  • In high-temperature media, the grease on the drive needs to be replaced every 30 days.

  • The drive must be protected against water leakage and damage to internal components.

  • The drive should not be covered by insulation material to avoid burning the motor.

  • When repairing the drive, the power must be cut off to prevent damage to the machine or cause leakage to death.

  • Do not touch or attempt to disconnect the line when the power is connected.

 

Technical Parameters of S6062-18/30A (D) Series Electric Actuator

 

Model

Parameters

S6062-18A

S6062-18D

S6062-30A

S6062-30D

Power

24VAC±15%

Torque

1800N

3000N

Control signal(Optional)

0~10VDC  2~10VDC

0~20mA   4~20mA

------

0~10VDC  2~10VDC

0~20mA   4~20mA

------

Control signal input impedance

Voltage:100K

Current:250Ω

------

Voltage:100K

Current:250Ω

------

Feedback Signal(Optional)

0~10VDC  2~10VDC

0~20mA   4~20mA

------

0~10VDC  2~10VDC

0~20mA   4~20mA

------

Feedback output load requirement

Voltage:>1K

Current:<=500Ω

------

Voltage:>1K

Current:<=500Ω

------

Power consumption

15VA

Stroke Time(40mm)

120 S

160 S

Maximum stroke

42mm

Manual operation function

Standard

Dimensions (standard type)

165*185*340(H)mm

 

High-temperature Drive Model Description of S6062-18/30A (D) Series Electric Actuator

 

When the drive bracket temperature is higher than 150 °C, it is recommended to use a high-temperature drive, the high-temperature drive product model is S6062- 18/30AG or S6062-18/30DG.

 

Wiring Diagram of S6062-18/30A (D) Series Electric Actuator

 

 

 

Type A Drive Operating Instructions of S6062-18/30A (D) Series Electric Actuator

 

1. Operation sequence

  • Connect the drive to the valve body.

  • Connect the power and control signal lines.

  • According to the application conditions, the DIP switch on the circuit board is set to the corresponding position. (See the setting instructions for details)

  • Turn on the power, turn on the power switch, the LCD screen of the driver and the corresponding LED indicator should be lit. Press the "red" auto-tuning button for about 3 seconds to perform the valve stroke self-tuning (see Self-tuning for details), the electric drive and After the auto-tuning process of the valve body is completed, the drive enters the normal operation and will operate according to the control signal at that time.

Do not disconnect the power supply and perform other operations during the drive auto-tuning process.

 

2. Valve position feedback signal introduction

  • The driver can provide real-time valve position feedback signal to the outside. The direction of change of the feedback signal always corresponds to the direction of change of the control signal. The type of feedback signal can be set by the DIP switch on the circuit board.

 

3. Manual operation

  • Disconnect the external power switch of the drive, the power indicator should be off.

  • Open the protective rubber plug on the top of the top cover of the drive to expose the manual operation hole.

  • Insert the special wrench attached to the top of the manual shaft

  • According to the description of the silkscreen of the upper cover, turn the wrench, rotate clockwise, the spindle runs downwards; turn counterclockwise, the spindle runs upwards.

  • After the manual operation is finished, remove the manual wrench, reset the rubber stopper, turn on the power switch, and enter the electric mode.

  • When the special wrench is not in use, please put it into the groove of the upper cover and press the wrench down to fix it to avoid loss. Once the manual wrench is lost, it can be operated using a standard 6mm Allen key.

 

Conmon Signal setting of S6062-18/30A (D) Series Electric Actuator

S6062-18/30A (D) Series Electric Actuator

 

 

Self-turning Process Description of S6062-18/30A (D) Series Electric Actuator

 

  1. Press the self-turning button for about 3 seconds, the LCD will display the interface as shown in Figure 1, the actuator will run downwards to detect the bottom position information. The LED indicator will flash when goes down and will be on when goes up. The second line of the LCD shows the current feedback potentiometer voltage value, which should be reduced as the actuator runs down.

  2. The actuator runs to the bottom, the spindle stops, and the feedback voltage value stops changing, the normal value should be about 0.5-0.8V.

  3. The actuator stays at the bottom about 20S and then starts to run upwards, and detects the top position information. The LED indicator will be on when goes down and will be flash when goes up. The second line of the LCD shows the current feedback potentiometer voltage value, which should be increased as the actuator runs down.

  4. The actuator runs to the top, the spindle stops, the feedback voltage value stops changing, and the normal value is related to the valve stroke size.

  5. The actuator stays at the top about 20 seconds and stores data.

  6. The LCD returns to the automatic operation interface and the auto-turning process

 

Automatic Control Mode of S6062-18/30A (D) Series Electric Actuator

  1. The first line is displayed as the setting status of the main DIP switch(see the instruction).

  2. The second line displays the current input and output signals in real-time.

  3. The right dynamic arrow is running status and direction information of the actuator

 

Manual Control Mode of S6062-18/30A (D) Series Electric Actuator

Turn the DIP switch S2-5 to the ON (up) position, the actuator enters into the manual control mode, and the LCD display interface is shown in Figure 3.

  1. Turn the DIP switch S2-6 to control the running direction of the actuator.

  2. Turn the DIP switch S2-5 to the OFF position, the actuator returns to the automatic control mode, and the LCD display returns to the automatic control interface.

 

PCB DIP Switch Setting Instruction of S6062-18/30A (D) Series Electric Actuator

 

S2 DIP switch

Function

Setting value function description

1

Sensitivity setting

ON

HS: High sensitivity

OFF

LS: Standard sensitivity

2

Control / valve position feedback signal starting point setting

ON

20%: The control/valve feedback signal starts at 20% (used for control/valve feedback signals of 4~20mA or 2~10VDC)

OFF

0: The control/valve feedback signal starts at 0 (used for control/valve feedback signals of 4~20mA or 2~10VDC)

3

Working mode setting

ON

DA: When the control signal is increasing, the actuator spindle extends out, and when the control signal is decreasing, the actuator spindle retracts.

OFF

RA: When the control signal is increasing, the actuator spindle retracts, and when the control signal is decreasing, the drive spindle extends out.

4

Break signal mode setting

ON

DW: When the control signal is set to voltage type or current type, if the signal line is cut off by this time, a minimum control signal is automatically provided inside the actuator.

OFF

UP:1) When the control signal is set to voltage type, if the signal line is cut off at this time, a maximum control signal is automatically provided inside the actuator.

2)When the control signal is set to current type, if the signal line is cut off at this time, a minimum control signal is automatically provided inside the actuator.

5

Automatic/manual mode conversion

ON

MO: Manual control mode: The change of the control signal on the terminal is no longer collected, and the running direction is determined by the status of manually dialing the dial code S2-6.

OFF

AO: Automatic control mode: Automatic operation and positioning according to the setting and the change of the control signal on the terminal.

6

Manual mode direction

ON

MO-UP: In manual mode, the actuator spindle runs up.

OFF

MO-DW: In manual mode, the actuator spindle runs down.

S3 DIP switch

Function

Setting value function description

1

Valve position feedback signal type setting

ON

I-OUT: The valve position feedback signal is current type.

OFF

V-OUT: The valve position feedback signal is voltage type

2

Control signal type setting

ON

I-IN: Control signal is current type

OFF

V-IN: Control signal is voltage type

 

Display Info of S6062-18/30A (D) Series Electric Actuator

 

 

Flag bit

Function

Description

 

LED indicator

POWER

POWER

It's always on when the main power of the actuator turn on

 

UP

UP

It will flash when the actuator spindle runs up

 

DOWN

DOWN

It will flash when the actuator spindle runs down

 

ERROR

ERROR

It will be on when the actuator is broken

 

MM

MM

It will be on when choosing the manual type

 

LCD

A

Signal start point

Display the current setting status of the DIP switch S2-2

 

B

Operating mode

Display the current setting status of the DIP switch S2-3

 

C

Input signal tyoe

Display the current setting status of the DIP switch S3-2

 

D

Output signal type

Display the current setting status of the DIP switch S3-1

 

E

Operating mode

Display the current setting status of the DIP switch S2-5

 

INPUT

Input signal type

Display the currently received control signal in real-time

 

OUTPUT

Output signal type

Display the currently output valve position signal in real-time

 

 

Accessories of S6062-18/30A (D) Series Electric Actuator

 

  • Instruction×1  

  • handle×1

 

Johnson interface installation diagram of S6062-18/30A (D) Series Electric Actuator

S6062-18/30A (D) Series Electric Actuator

 

 

Siemens interface installation diagram of S6062-18/30A (D) Series Electric Actuator

S6062-18/30A (D) Series Electric Actuator

 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
78
Year of Establishment
2000-04-25