Exs6061sf-05/10/15dfk-5 Explosion-Proof Actuator

Certification: ISO, CE
Power Supply: AC DC24V AC230V
Power Source: Electric Power
Temperature: Ordinary Temperature
Transport Package: Cartons
Trademark: SOLOON
Samples:
US$ 750/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2021

Suppliers with verified business licenses

Beijing, China
to see all verified strength labels (30)

Basic Info.

Model NO.
ExS6061SF-05/10/15DFK-5
Origin
China
Production Capacity
1000per Month

Product Description

ExS6061SF-05/10/15DFK-1/24(230)V

         Model
Para.
ExS6061SF-05DFK-1/24V ExS6061SF-10DFK-1/24V ExS6061SF-15DFK-1/24V ExS6061SF-05DFK-1/230V ExS6061SF-10DFK-1/230V ExS6061SF-15DFK-1/
230V
Torque 5Nm;10Nm;15Nm
Damper Size 1m2;                                             3m2;                                   4.5m2
Power Supply AC230V  AC24V  DC24V 50/60Hz  i ≤0.2A
AC220V 50/60Hz
Consumption 7W run/3W remain;10W run/3W remain;12W run/3W remain
Wire Size 10VA
Connection cable Power:1m cable  3*0.5 m2
  Auxiliary Switch  (F):1m cable 6*0.5 m2
Running Time Motor≤15s;Spring Return≤1s
Angle of Rotation Max 93º
Position Indication Mechanical indicator
Weight 5Kg
Life  Cycle ≥1000 cycles
Sound  Level 50dB(A)and62dB(A)
Protection Level (safety low voltage) (full insulation)
IP Protection IP66
Temperature -20~+60ºC
Ambient Temperature 5~95%RH
Explosion-proof Mark Ex db  B  T6 T5 Gb    Ex tb IIIC T85°C Db
-20ºC≤Ta≤+55ºC (T6)
  -20ºC≤Ta≤+60ºC  (T5 and T85ºC)
Features:
  1. Single control
  2. Form-fit 12x12 shaft
  3. Universal shift plug
  4. Two auxiliary switches
  5. Cast aluminum housing, compacting type
  6. Safety meets IP66
Compliances:
  1. IEC60079-0:2017, EN60079-0:2018 electrical apparatus in explosive gas atmosphere - part0:  General requirements.
  2. IEC60079-1:2014, EN60079-1:2014 electrical apparatus in explosive gas atmosphere - part1:flameproof"d".
  3. IEC60079-31:2013,EN60079-31:2014  explosive atmospheres part31: Equipment dust ignition  protection by enclosure "t".
Usage:  
  1. Cable connector and the housing mating thread size M16 × 1.5, cable diameter size Φ6-Φ8. When the equipment is used on site, the cable gland should be installed by user, whose protection grade should not be lower than 2D Ex tb IIIC T85°C Db.
  2. Within ground terminal tightening torque 2N.m.
  3. Flameproof joint tightening torque is 3.2N.m.
  4. External ground bolt M4X6, pressing 4mm² conductor.
  5. The entry shall be equipped with Ex certified cable glands with a compatible mode of protection for the intended use.


Maintenance:
  1. When  assembly,  operation  and  maintenance,   the operator  should  follow  the  requirements  of EN 60079-14, beside of the instruction manual.
  2. Repair  and  overhaul  shall  comply  with  EN 60079-19.
  3. The product shell is cleaned with wet cloth and the user is forbidden to repair and modify the flameproof content.
Warning:
  1. Disassembly is prohibited without permission Do not open with power. please do not open the cover in the explosive gas. Need to use a damp cloth when opening.l
  2. AFTER DE-ENERGIZING, DELAY 10 MINUTES BEFORE OPENING.
  3. DO NOT OPEN WHEN ENERGIZED.
  4. POTENTIAL ELECTROSTATIC HAZARD - SEE INSTRUCTIONS.
  5. USE FASTENERS WITH YIELD STRESS >=450MPa
  6. The flame-proof joints cannot be repaired or modified by user.
  7. Installation must be carried out by personnel with relevant training or working experience. During installation,pls do not operate  with electric and in accordance with the regulations.
  8. There are electrical and electronic parts in the device, so it is forbidden to disposal as ordinary garbage after the product is scrapped. The disposal method should comply with the local government's regulations and requirements.






Electrical connection and out line:  

Exs6061sf-05/10/15dfk-5 Explosion-Proof Actuator



Description of product function and application:
  1. Explosion-proof electrical appliances refer to a class of electrical equipment used in places where explosive gases and vapors exist.
  2. Coal, petroleum, chemical, textile and other industries in the national economy occupies a very important position, these industries in the production process will produce explosive gas.Steam or explosive dust, such places are called explosive dangerous places.
  3. Our company produces the explosion-proof type air valve actuator as part of the not mine explosion-proof electrical equipment. 90% of mine explosion-proof electrical equipment is used in oil, chemical, pharmaceutical and other industries) (hereinafter referred to as petrochemical industry, inflammable and explosive gas/steam is common and combustible dust existing environment/work sites and at the same time.

Special condition of use:
  1. The flame-proof joints cannot be repaired or modified by user.
  2. The entry shall be equipped with Ex certified cable glands with a compatible mode of protection for the intended use.
  3. When assembly, operation and maintenance, the operator should follow the requirements of EN 60079-14, beside of the instruction manual.
  4. Repair and overhaul shall comply with EN 60079-19.
Exs6061sf-05/10/15dfk-5 Explosion-Proof ActuatorExs6061sf-05/10/15dfk-5 Explosion-Proof Actuator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
78
Year of Establishment
2000-04-25